Telemetry2U Technical Bulletin

25 mL Glycol-Equivalent Temperature Sensor Buffer

A liquid-free temperature buffer designed to reproduce the thermal response of a 25 mL glycol-filled reference bottle while providing secure probe mounting and a dedicated thermowell for rapid onsite temperature verification.

Thermal reference: 25 mL glycol bottle Operating range: -30°C to +40°C Approx. size: 40 mm diameter × 45 mm high Two thermowells: monitoring + reference

Why use a temperature sensor buffer?

The air temperature inside a fridge, freezer or incubator can change much faster than the temperature of the products, medicines or samples stored inside it. Door openings, defrost cycles and local airflow can therefore cause short-lived temperature excursions that are not representative of the monitored contents.

A temperature buffer adds controlled thermal mass around the sensor. The probe responds more gradually to changes in the surrounding air, producing a trend that more closely represents the thermal behaviour of stored material rather than the fastest-changing air temperature.

Reduce transient fluctuations

Damp short temperature changes caused by airflow, door openings and normal refrigeration operation.

Represent stored products

Follow a response profile that is closer to liquids and stored samples than an unbuffered air-temperature probe.

Support verification

Insert a reference thermometer beside the installed monitoring probe without removing the installed monitoring probe.

Engineered composite design for permanent monitoring

The Telemetry2U buffer is manufactured from an engineered composite polymer and is designed around the practical requirements of permanently installed temperature monitoring sensors.

Upright view of the Telemetry2U 25 mL glycol-equivalent temperature sensor buffer
Upright buffer with integrated probe-retention post and central mounting groove.
Top view of the Telemetry2U temperature sensor buffer showing two thermowells and the cable-retention post
Dual thermowells and integrated cable-retention post.
Side view of the Telemetry2U temperature sensor buffer showing its central cable-tie mounting groove and retention post
Central mounting groove and side profile.

Two thermowells

Every buffer includes a dedicated 5.2 mm reference thermowell suitable for the Traceable Memory-Loc bullet-style reference probe.

The second thermowell is selected to suit the permanently installed monitoring probe.

Secure probe retention

A small post with a retaining groove allows the sensor cable to be secured with a cable tie so the probe cannot easily work loose during normal loading, cleaning or servicing.

The arrangement also helps maintain a repeatable insertion position.

Shelf mounting

A circumferential groove around the centre of the body provides a defined cable-tie position when securing the buffer to a wire shelf.

Wall mounting

A flat rear surface allows the buffer to be mounted against the side or rear wall of a fridge, freezer or incubator using a suitable adhesive method.

Standard thermowell configurations

The reference thermowell is always 5.2 mm. The monitoring thermowell is selected according to the sensor used at the site.

Standard and custom thermowell arrangements
Reference well Monitoring well Typical use
5.2 mm 6.0 mm Dragino LHT65S and other 6 mm temperature probes
5.2 mm 5.2 mm Dragino LTC2-LB-CB and other approximately 5 mm probes
5.2 mm Custom Custom probe diameter on request

Thermowell depth is matched to the sensor where practical. For example, the 6 mm Dragino LHT65S probe is inserted approximately 35 mm so the thermowell matches the probe length. For other sensors, the sensing tip is positioned close to the centre of the buffer where possible.

Fast onsite temperature verification

A major advantage of the dual-well design is that the installed monitoring probe and the reference probe can be compared inside the same thermal mass.

The monitoring sensor can remain installed in its normal operating position while a Traceable Memory-Loc bullet probe or another suitable calibrated reference sensor is inserted into the 5.2 mm reference thermowell. Because both sensing elements are inside the same buffer, the comparison can stabilise quickly without requiring two separate bottles or independently buffered probes.

Compared directly with a Traceable Memory-Loc glycol bottle

Telemetry2U developed the standard buffer around the thermal behaviour of the commonly used Traceable Memory-Loc glycol-filled bottle. The test below compares the Telemetry2U buffer directly against that reference arrangement.

Both devices were stabilised in a freezer and then allowed to warm towards room temperature. In the comparison data, Series 1 represents the Memory-Loc bottle. The two temperature curves track closely throughout the approximately 45-minute warm-up period.

Temperature chart showing the Traceable Memory-Loc 25 millilitre glycol bottle and Telemetry2U 25 millilitre buffer following a closely matched freezer warm-up curve
Freezer warm-up comparison of the Telemetry2U buffer and Memory-Loc glycol bottle. The two response curves remain closely aligned through the measured temperature change.

This result supports the use of the standard Telemetry2U buffer as a practical liquid-free alternative where a temperature response similar to a 25 mL glycol-filled reference bottle is required.

These results apply to the test conditions described above. Actual response can vary with probe fit, airflow, placement, cabinet loading and the thermal characteristics of the monitored contents.

Custom probe sizes and custom thermal profiles

The standard product is designed around a 25 mL glycol-equivalent response, but both the probe fit and the thermal profile can be customised where required.

Custom thermowell diameter

The 5.2 mm reference thermowell remains standard while the monitoring thermowell can be produced to suit another probe diameter.

Custom-hole fee: $50.

Custom glycol-equivalent profile

Telemetry2U can develop a buffer to emulate another nominated glycol volume, such as 65 mL.

Development fee: $500. Minimum order: 50 units.

A custom thermal profile can be based on agreed bottle dimensions and glycol volume, or a physical reference sample supplied to Telemetry2U. The completed profile will be supported by documented warming and cooling comparison tests.

Order the standard 25 mL glycol-equivalent temperature sensor buffer directly from the Telemetry2U online store.